EOCR-3DE Overview

✔ Built-in MCU (Microcontroller Unit)

✔ Real-time processing / High accuracy

✔ Overcurrent protection range: 05: 0.5~7A, 80: 5~80A

✔ Secondary current transformer ratio setting: 1A / 5A

✔ Undercurrent protection range: Set below overcurrent

✔ Operating time characteristics: Definite time / Inverse time

✔ Undercurrent trip output

✔ Common output for undercurrent output and OC output

✔ AL output (07-08) automatically switches to dedicated undercurrent (UC) output contact

✔ Digital display screen

✔ Automatic three-phase current cyclic display: Digital ammeter (each phase at 5-second intervals) / Fixed-phase management function through manual cycling

✔ Trip cause digital display: Simple fault, self-diagnosis function

✔ Final trip cause confirmation function: Records the causes of the last three trips and current confirmation at the time of the trip

✔ Confirmable even when power is restored

✔ Manual (immediate) / Automatic reset

✔ Fault protection function (FS: ON)

✔ Self-diagnosis function: Relay power-on, normal operation (selectable by setting)

✔ 35mm DIN rail mounting, suitable for various environments

✔ Suitable for variable frequency systems: 20~400Hz

✔ Terminal type and through type selectable

EOCR3DE-05DUH

EOCR3DE-80DUH

EOCR3DE-05DUT

EOCR3DE-80DUT


Protection Functions

✔ Overcurrent (Definite Time: 0.5...30 seconds, Inverse Time: 1...30 class)

✔ Undercurrent (0.5...30 seconds)

✔ Phase Loss (within 3 seconds)

✔ Reverse Phase (0.1...0.3)

✔ Current Imbalance (within 8 seconds)

✔ Locked Rotor (after D-Time)


EOCR-3DE Product Features

产品规格

Product RangeEOCR

Product NameEOCR-3DE Electronic Overcurrent Relay

Product Type

• Overload protection, set value (In > Overcurrent setting value)

• Under-current protection, set value (In < Under-current setting value)

• Locked rotor protection during operation, set value (In > 1.5...5 times the overcurrent setting value)

• Phase failure protection

• Reverse phase protection

• Locked rotor protection during startup, set value (In > 2...10 times the overcurrent setting value)

• Unbalance protection (5...50%)


[Us] Rated 

Input Voltage

100~240V AC / AC


Power Frequency50...60 Hz

Relay ApplicationMotor protection

Protection Range• 05:0.5-7 A
• 80:5-80 A
• When used beyond the main body range with type 05 and 3CT, it can protect up to 960A.

Mounting Method

35mm DIN rail mounting or screw fixing


Electrical/Mechanical Characteristics

Contact Type 

• 1 NC + 1 NO OL): One normally closed contact and one normally open contact, used for overload protection.

• 1 NO AL): One normally open contact, used for alarm function.


[[Ue] Rated 

Operational Voltage

600 V AC 50...60 Hz Main Circuit Conforming to UL

690 V AC 50...60 Hz Main Circuit Conforming to CSA

690 V AC 50...60 Hz Main Circuit Conforming to IEC 60947-4-1


[Uimp] Rated Impulse 

Withstand Voltage

6 kV Conforming to IEC 60947-4-1


Reset MethodManual reset / Electric reset / Automatic reset

Time SettingOvercurrent operation time 1...30 levels (inverse time)

Display Type

Bar graph and 7-segment LED display


Power Consumption 5 W

[lth] Continuous Current3 A control circuit

Permissible Current100...240 V,3 A

Wiring

Control circuit cable 2 x 1…1.5 mm² flexible cable with terminal - M3

Control circuit cable 2 x 1…1.5 mm² flexible cable without terminal


Tightening Torque

Control circuit 0.8...1.2 N·m suitable for 4.7 mm cable.


Dimensions and Weight

Height

56.3 mm


Width

70 mm


Depth

106 mm


Weight

0.27 kg


Using Environment

Using Temperature
Matching IEC 60947-4-1, -20…60 °C

Storage Temperature
-40…85 °C

Using Altitude
2000m

IP Rating
IP20 conforming to IEC 60529

Fire Resistance
650°C, compliant with IEC 60695-2-12 standard.

Shock Resistance
15 gn 11 ms compliant with IEC 60068-2-7

Vibration Resistance

- Panel mounting: 4 gn, compliant with IEC 60068-2-6

- 35 mm rail mounting: 2 gn, compliant with IEC 60068-2-6


Surge Withstand
6 kV compliant with IEC 61000-4-5

Dielectric Strength

2 kV 50...60 Hz between enclosure and circuit in compliance with IEC 60255-5

1 kV 50...60 Hz between contacts in compliance with IEC 60255-5

2 kV 50...60 Hz between internal circuits in compliance with IEC 60255-5


Electromagnetic 

Compatibility

- Radiated RF immunity 10 V/m level 3 in accordance with IEC 61000-4-3

- Electrostatic discharge immunity 8 kV air, 6 kV contact in accordance with IEC 61000-4-2

- Transient overvoltage 2 kV in accordance with IEC 61000-4-4

- Conducted RF immunity 10 V in accordance with EN 61000-4-6

- Conducted RF emission class A in accordance with EN 55011


Certifications and Standards

Standards
Conforms to IEC 60947-4-1

Certifications
CE Certification

18 Months Warranty


EOCR-3DE  Reference Wiring

3DE-OFF - 副本.png

3DE-ON - 副本.png

EOCR-3DE  Dimensions

EOCR3DE-80DUH_IMAGE_1500x1500.png

外形图一体体式-2.png

EOCR3DE-05DUT.png

外形图一体体式-1.png



EOCR-3DE  Product Ordering

3DE-选型.png


Online consultation

If you are interested in our products, or if we can help you, you can call our national customer service number at any time:+86-17717479099

You can also communicate with us online, of course, you can also leave us a message below, we will be happy to serve you!